ALARM & NOTIFICATION

Make the warning
clear to every occupant.

Design audible and visual alarm coverage around ambient noise, occupancy, accessibility, zoning and the building evacuation strategy.

Explore the full solution
CONVENTIONAL SOUNDER-STROBE / ADDRESSABLE SOUNDER-STROBE / CALL POINT

DESIGN AROUND THE OUTCOME

Four decisions shape a dependable system.

Products perform best when architecture, environment, capacity and the operating workflow are considered together.

AUDIBILITY

Audibility

Establish sound levels and tone strategy against ambient noise and occupied use.

VISIBILITY

Visibility

Use visual alarm devices where noise, hearing accessibility or building conditions require them.

ZONING & SEQUENCE

Zoning & sequence

Coordinate alarm, evacuation, delay and phased-operation logic with the fire strategy.

SUPERVISION

Supervision

Monitor circuits, isolators and device status so faults are visible before an emergency.

UNDERSTAND THE SYSTEM ROLES

Select by responsibility—not appearance.

Representative capabilities help establish the architecture. Final models and quantities are verified during system design.

01Teletek SF100 RSST Sounder & StrobeTeletekSF100 RSST Sounder & Strobe

SYSTEM ROLE / 01

Conventional sounder-strobes

SF100 RSST provides 32 tones, selectable 94 or 102 dB output and separate alarm/evacuation inputs.

TYPECONVENTIONAL
TONES32
OUTPUT94 / 102 DB
INPUTSALARM + EVACUATION
  • Audible and visual warning in one unit
  • Evacuation input receives priority
  • Compact indoor wall mounting
02Teletek SensoIRIS WS IS Sounder & StrobeTeletekSensoIRIS WS IS Sounder & Strobe

SYSTEM ROLE / 02

Addressable loop notification

SensoIRIS WS IS is loop-powered with panel-selected tones, two output ranges, built-in isolation and synchronized signalling.

TYPEADDRESSABLE
TONES32
OUTPUT80–98 DB
ISOLATORBUILT IN
  • Point-level supervision
  • Synchronized notification on the loop
  • IP65 base option for suitable locations
03Teletek SensoIRIS MCP150PR Call PointTeletekSensoIRIS MCP150PR Call Point

SYSTEM ROLE / 03

Manual call points

MCP150PR gives occupants a clear addressable way to initiate an alarm using glass or resettable operating elements.

TYPEADDRESSABLE
OPERATIONTYPE B
ELEMENTGLASS / RESETTABLE
ISOLATORBUILT IN
  • Recognizable manual alarm point
  • Addressable location information
  • Loop-powered with isolation

Representative Teletek notification and initiating-device information. Audibility, visibility and evacuation sequencing require project-specific calculation and approval.

FROM REQUIREMENT TO OPERATION

The equipment becomes valuable when the complete path works.

Zicore connects field devices, infrastructure, control, user workflow and maintenance as one delivery responsibility.

  1. 01

    Discover

    Map the site, risk, users, environment and operating responsibility.

  2. 02

    Engineer

    Define architecture, capacity, interfaces, power, network and resilience.

  3. 03

    Deliver

    Install, configure and integrate equipment as one coordinated system.

  4. 04

    Prove

    Test real scenarios, document the result and enable the responsible team.

BRANDS IN THIS SYSTEM

Specialist portfolios. One engineered outcome.

Zicore selects from the brands we distribute or partner with, then verifies compatibility across the complete design.

START WITH THE REQUIREMENT

Tell us what the system
must help your team do.

Share the site, scale, risks, existing equipment, operating workflow and future plans.

LET’S TALK

Tell us what
you have in mind.

Choose how we can help.

Your details are emailed to Zicore so our team can reply.